Macken Instruments

簡易型レーザパワープローブ

レーザパワープローブマッケンインスツルメンツ社 (米国) の、レーザパワープローブは
取り扱いが容易で、低価格にて提供しています。

携帯に便利でセッティングの手間もかかりません。
日常点検のパワー管理などに最適です。

この他に、赤外レーザのビームパターン用のイメージプレートや、
波長確認用のスペクトルアナライザもあります。

Yタイプ(YAG / ファイバレーザ向け)

  Model Power
Range
(W)
Wavelength
(nm)
Damage
Threshold
(Max Power)
Exposure
Time
Watts/
Division
Absorbing
Head
(cm)
Overall
Length
(cm)
P20Y P20Y 0-2 900 - 1250* 3000W/cm² 30 sec. 0.2 4.58×2.54
(1.8"×1")
22
P50Y P50Y 0-50 3000W/cm² 20 sec. 0.5 4.58×2.54
(1.8"×1")
22
P100Y P100Y
0-100 3000W/cm² 20 sec. 1 5.08×3.18
(2"×1.25")
22
P200Y P200Y
0-200 2500W/cm² 20 sec. 2 5.08 dia.
(2" dia.)
22
P500Y P500Y
0-500 2000W/cm² 20 sec. 5 5.08 dia.
(2" dia.)
22
P1000Y P1000Y
0-1000 1750W/cm² 20 sec. 10 6.35 cm dia.
(2.5" dia.)
22
P2000Y P2000Y
0-2000 1200W/cm² 20 sec. 20 7.62 dia.
(3" dia.)
22
P4000Y P4000Y
0-4000 900W/cm² 20 sec. 25 8.89 dia.
(3.5")
28
P10KY P10KY 0-5,000W
0-10kW
750W/cm² 20 sec.
10 sec.
50
100
8.89 dia.
(3.5")
28

Cタイプ(CO₂レーザ向け)

  Model Power
Range
(W)
Wavelength
(µm)
Damage
Threshold
(Max Power)
Exposure
Time
Watts/
Division
Absorbing
Head
(cm)
Overall
Length
(cm)
P100C P100C 0-100 8 - 11 10,000W/cm² 20 sec. 1 5.08×3.18
(2"×1.25")
22
P200C P200C 0-200 7000W/cm² 20 sec. 2 5.08 dia.
(2" dia.)
22
P500C P500C 0-500 4000W/cm² 20 sec. 5 5.08 dia.
(2" dia.)
22
P1000C P1000C 0-1000 2500W/cm² 20 sec. 10 6.35 dia.
(2.5" dia.)
22
P2000C P2000C 0-2000 1500W/cm² 20 sec. 20 7.62 cm dia.
(3" dia.)
22
P4000C P4000C 0-4000 1100W/cm² 20 sec. 25 8.89 dia.
(3.5")
28
P10KC P10KC 0-5,000W
0-10kW
900W/cm² 20 sec.
10 sec.
50
100
8.89 dia.
(3.5")
28

レーザパワープローブ*Y type probe wavelength range - These probes are calibrated at 8-11µ as well, but have a lower damage threshold for this range than the C type probes. Calibration for any wavelength between 250nm – 2500nm is available upon request with an NIST certificate.

‡Damage Threshold - Moving the probe during exposure will increase (up to double) the damage threshold compared to the numbers shown for a stationary probe. To achieve this increase, the head must be moved in a circular motion so that the laser beam does not strike any one area continuously for more than 1.5 seconds.

§Accuracy and Exposure Time - The accuracy and repeatability of the Power Probes partly depends on the accuracy of the exposure time. The average accuracy of exposures (hand held) has been found to be 0.2 seconds. This amounts to a 1% error for a 20 second exposure time. Many lasers are equipped with a shutter that can produce an exact time exposure.

質問をクリックすると回答がご覧になれます。

プローブは頑丈ですか?
長時間、同じ場所にレーザを照射し続けると、プローブがダメージを負うことがあります。
校正サービスはありますか?
サービスはありますが、別途有償となります。