簡易型レーザパワープローブ

レーザパワープローブマッケンインスツルメンツ社(米国)の、レーザパワープローブは取り扱いが容易で、低価格にて提供しています。

携帯に便利でセッティングの手間もかかりません。日常点検のパワー管理などに最適です。

この他に、赤外レーザのビームパターン用のイメージプレートや、波長確認用のスペクトルアナライザーもあります。

Model Power Range Wave-
length
Damage
Threshold
(Max Power)
Exposure
Time
Watts/
Division
Absorbing
Head
Overall
Length
(cm)
Weight
(gm)
P20Y 0-20W 900-1250nm* 3000W/cm² 30 sec. 0.2 4.58×2.54 cm
(1.8"×1")
22 89
P50Y 0-50W 900-1250nm* 3000W/cm² 20 sec. 0.5 4.58×2.54 cm
(1.8"×1")
22 98
P100Y
0-100W 900-1250nm* 3000W/cm² 20 sec. 1 5.08×3.18 cm
(2"×1.25")
22 120
P100C 0-100W 8µ - 11µ 10,000W/cm² 20 sec. 1 5.08×3.18 cm
(2"×1.25")
22 120
P200Y
0-200W 900-1250nm* 2500W/cm² 20 sec. 2 5.08 cm dia.
(2" dia.)
22 157
P200C 0-200W 8µ - 11µ 7000W/cm² 20 sec. 2 5.08 cm dia.
(2" dia.)
22 157
P500Y
0-500W 900-1250nm* 2000W/cm² 20 sec. 5 5.08 cm dia.
(2" dia.)
22 183
P500C 0-500W 8µ - 11µ 4000W/cm² 20 sec. 5 5.08 cm dia.
(2" dia.)
22 183
P1000Y
0-1000W 900-1250nm* 1750W/cm² 20 sec. 10 6.35 cm dia.
(2.5" dia.)
22 287
P1000C 0-1000W 8µ - 11µ 2500W/cm² 20 sec. 10 6.35 cm dia.
(2.5" dia.)
22 287
P2000Y
0-2000W 900-1250nm* 1200W/cm² 20 sec. 20 7.62 cm dia.
(3" dia.)
22 522
P2000C 0-2000W 8µ - 11µ 1500W/cm² 20 sec. 20 7.62 cm dia.
(3" dia.)
22 522
P4000Y
0-4000W 900-1250nm* 900W/cm² 20 sec. 25 8.89 cm dia.
(3.5")
28 753
P4000C 0-4000W 8µ - 11µ 1100W/cm² 20 sec. 25 8.89 cm dia.
(3.5")
28 753
P10KY 0-5,000W
0-10kW
900-1250nm* 750W/cm² 20 sec.
10 sec.
50
100
8.89 cm dia.
(3.5")
28 1144
P10KC 0-5,000W
0-10kW
8µ - 11µ 900W/cm² 20 sec.
10 sec.
50
100
8.89 cm dia.
(3.5")
28 1144

レーザパワープローブ*Y type probe wavelength range - These probes are calibrated at 8-11µ as well, but have a lower damage threshold for this range than the C type probes. Calibration for any wavelength between 250nm – 2500nm is available upon request with an NIST certificate.

‡Damage Threshold - Moving the probe during exposure will increase (up to double) the damage threshold compared to the numbers shown for a stationary probe. To achieve this increase, the head must be moved in a circular motion so that the laser beam does not strike any one area continuously for more than 1.5 seconds.

§Accuracy and Exposure Time - The accuracy and repeatability of the Power Probes partly depends on the accuracy of the exposure time. The average accuracy of exposures (hand held) has been found to be 0.2 seconds. This amounts to a 1% error for a 20 second exposure time. Many lasers are equipped with a shutter that can produce an exact time exposure.

プローブは頑丈ですか?

長時間、同じ場所にレーザを照射し続けると、プローブがダメージを負うことがあります。

校正サービスはありますか?

サービスはありますが、別途有償となります。